HAWKEYE
Monitoring/Technical Specifications
SYSTEM SPECIFICATIONS |
||
Hazardous area approval |
EExd [ia] IIB T6 (Zone 1) |
|
ATEX certificate |
SIRA 04ATEX1028X |
|
System |
Single enclosure and remote sensor |
|
Unit dimensions |
Height 350mm, width 145mm, depth 120mm |
|
POWER SUPPLY |
||
Battery pack |
3.9v lithium-thionyl chloride battery pack |
|
Battery life |
More than three years (depending on unit configuration) |
|
Battery change |
Field replaceable pack |
|
SENSOR SPECIFICATIONS |
||
Primary |
||
Sensor type |
Downward looking ultrasonic sensor |
|
Measurement range |
0.3 – 6 metres |
|
Blanking range |
0.3 metres |
|
Measurement uncertainty |
+/- 0.25% for MAX measurement span (or 10mm whichever is greater) |
|
Resolution |
+/- 3mm |
|
Beam angle |
10° +/- 2° |
|
Temperature compensation |
Ultrasonic head temperature |
|
Process connection |
1” BSP thread |
|
Sensor cable length |
10 metres as standard (longer lengths on request) |
|
Secondary Channel Sensors |
Druck IS pressure sensor input |
|
DATA LOGGER |
||
Memory capacity |
1 month at 1 minute logging interval |
|
Memory type |
Non-volatile |
|
Firmware |
Flash upgradeable |
|
ENVIRONMENTAL |
||
Memory capacity |
1 month at 1 minute logging interval |
|
Memory type |
Non-volatile |
|
Firmware |
Flash upgradeable |
|
COMMUNICATIONS |
||
Direct communication |
RS232 via cable |
|
Remote communication options |
Wireless GSM / PNC via CSD |
|
Communications protocols supported |
Modbus ASCII, Logica Medina, Please contact IETG for more details |
|
FEATURES |
||
Easy to use configuration software |
||
System information |
|
Battery voltage |
Level measurement methods |
|
Level measurement as % of weir wall height |
User programmable Daily Check-in |
|
Automated data retrieval and health check |
User programmable Alarm Triggers 4 set points |
|
Set point exceedance alarm |
Alarm hysteris value |
|
User programmable |
Alarm trigger reduction |
|
Reduces alarms sent by delaying the sending of the alarm |
| [ Back to Top ] | ||