HAWKEYE
Monitoring/Technical Specifications
SYSTEM SPECIFICATIONS |
||
Hazardous area approval |
EExd [ia] IIB T6 (Zone 1) |
|
ATEX certificate |
SIRA 04ATEX1028X |
|
Sealing standard |
IP68 (up to one metre) |
|
Operating temperature range |
-20 to +60 |
|
Enclosure |
Single enclosure and remote sensor |
|
Connectors |
Industrial Connectors (IP67) |
|
Power supply |
Six alkaline D cells, field replaceable |
|
Battery life (between replacement) |
Minimum one year (at fifteen minute logging intervals) |
|
SENSOR SPECIFICATIONS |
||
Sensor type |
Downward looking ultrasonic sensor |
|
Measurement range |
0.3 – 6 metres (minimum) |
|
Blanking range |
0.3 metres |
|
Measurement uncertainty |
+/- 0.25% for MAX measurement span |
|
Resolution |
3mm |
|
Beam angle |
10° +/- 2° |
|
Temperature compensation |
Internal to unit |
|
Process connection |
1” BSP thread |
|
Sensor cable length |
10 metres as standard |
|
Float switch input |
ATEX approved float switch (volt free) |
|
DATA LOGGER SPECIFICATIONS |
||
Data logger type |
ISODAQ XL series logger |
|
Channels |
Single channel logger |
|
Memory capacity |
One month at one minute logging interval |
|
Memory type |
Non-volatile memory |
|
Firmware |
XF firmware, flash upgradeable |
|
DIMENSIONS |
||
Height |
350mm |
|
Width |
145mm |
|
Depth |
120mm |
|
COMMUNICATIONS |
||
Direct communication |
RS232 via cable |
|
Remote communication options |
GSM |
|
Communications protocols |
MODBUS ASCII, DNP3, Logica Medina |
|
Alarm triggers |
User programmable: |
|
Alarm outs |
Direct to client telemetry system |
|
Dial outs |
User programmable: |
|
Interface |
Client telemetry system via MODBUS ASCII Protocol |
|
| [ Back to Top ] | ||